Type [ru]

  • AE0701 Length positioning of Woodbinders [ru]

    AE0701 Length positioning of Woodbinders [ru]

    Spruce wood has been produced at our customers facility for decades with great care and professional competence and is not a freely interchangeable product. Because the big difference is in countless details that have been perfected over the many years. Our customer has the most modern know-how for the production of cuttings for a wide range of applications such as planking, timber construction, roof constructions, pallet production etc. Dimetix lasers are used daily. The truss length is used for positioning and to enhance their operational efficiency.
  • AE0104 Floodgate position measurement [ru]

    AE0104 Floodgate position measurement [ru]

    In times of floodwater, floodgates guarantee the controlled efflux of the enormous house of water. It is necessary to know the exact position of the floodgates, in order to determine the amount of overflow. DIMETIX sensors measure the position of the floodgates milli-meter precise and absolutely contactless.
  • AE0104 Floodgate position measurement [ru]

    AE0104 Floodgate position measurement [ru]

    In times of floodwater, floodgates guarantee the controlled efflux of the enormous house of water. It is necessary to know the exact position of the floodgates, in order to determine the amount of overflow. DIMETIX sensors measure the position of the floodgates milli-meter precise and absolutely contactless.
    AE0401 Truck position measurement [ru]

    AE0401 Truck position measurement [ru]

    In times of increasing traffic and ever more demanding tasks where time is of the essence, a system was developed to speed up customs checks on HGV vehicles. This device helps to significantly reduce time consuming check ups on vehicles since the positioning of the trucks is done with sensors. Customs uses mobile X-Ray scanners to check the content of trucks and containers. During the scanning process the movement of the scanner must be determined precisely.
    AE0701 Length positioning of Woodbinders [ru]

    AE0701 Length positioning of Woodbinders [ru]

    Spruce wood has been produced at our customers facility for decades with great care and professional competence and is not a freely interchangeable product. Because the big difference is in countless details that have been perfected over the many years. Our customer has the most modern know-how for the production of cuttings for a wide range of applications such as planking, timber construction, roof constructions, pallet production etc. Dimetix lasers are used daily. The truss length is used for positioning and to enhance their operational efficiency.
  • AN2001 Numeric digital display [ru]

    AN2001 Numeric digital display [ru]

    This application note shows how to display a measured distance value on a standard external numeric digital display. Description of the wiring and sensor configuration are included as well as two samples are given.

    AN2002 SSI interface usage [ru]

    AN2002 SSI interface usage [ru]

    The FLS-C(H) provides a Synchronous Serial Interface (SSI). SSI is a widely used serial interface standard for industrial applications between a master (e.g. controller) and a slave (e.g. FLS-C). On an SSI communication channel, the master generates a clock, while the slave sends the data corresponding to the received clock signal. Only point to point communication is possible with the SSI interface. The RS-422 standard defines the electrical signal levels of the SSI interface.

    AN2003 RS-422 connection to RS-485 [ru]

    AN2003 RS-422 connection to RS-485 [ru]

    This document explains how to connect the RS-422 interface of the DLS/FLS-C device ot a RS485 two wire interface. This application note requires special skils, therefore it must be requested by e-mail.
    AN2004 EXCEL Example [ru]

    AN2004 EXCEL Example [ru]

    This application note describes how to control a Dimetix distance sensor connected to a serial interface by VBA (Visual Basic for Application). The VBA program is integrated into an EXCEL worksheet.
    AN2005 S7 Profibus connection example [ru]

    AN2005 S7 Profibus connection example [ru]

    This application notes describe the connection of the DIMS Profibus converter to a S7 PLC and a DLS / FLS device. The S7 sample project is also available for download on our web site.

    AN2006 Timed measurement characteristic example [ru]

    AN2006 Timed measurement characteristic example [ru]

    The DLS-C and the FLS-C Laser distance sensor offers configuration possibilities for fix timed measurements. This application note gives some configuration examples and describe the specialities of the timed measurement characteristic.
    AN2010 S7 connection by RS422 [ru]

    AN2010 S7 connection by RS422 [ru]

    This application notes describe how to connect a DLS / FLS to a CP340 interface of a Siemens S7 PLC. The configuration and the wiring is described. In addition to this application note an example for the S7 is also available on our website.
    AN2018 Moving target characteristic with RS-422 [ru]

    AN2018 Moving target characteristic with RS-422 [ru]

    The "Moving target characteristic" is made for fast position measuring on continuous moving targets. This document describes the necessary settings of the FLS-C sensor for the "Moving target characteristic" as well as the configuration of the RS-422 interface.
    AN2019 Moving target characteristic with SSI [ru]

    AN2019 Moving target characteristic with SSI [ru]

    The  Moving target characteristic is made for fast position measuring on continuous moving targets. This document describes the necessary settings of the FLS-C sensor for the "Moving target characteristic" as well as the configuration of the SSI and Analog interface.
    AN2020 Positioning with SEW drives [ru]

    AN2020 Positioning with SEW drives [ru]

    This document describes how to use the FLS-C sensor in a positioning application in conjunction with a SEW servo drive. The necessary configuration of the FLS-C and the configuration of the SEW inverter are described . Further the wiring is also documented.